Flame Retardent Cables Anti-Rodent, Anti-Termite
The manufacturing unit is managed by a team having vast experience in cable assembling, testing and management fields. It has technically qualified and experienced workforce. The team ensures efficient functioning of the company’s activities to offer its customers, products & services of the highest standards.
Panel Wiring, Building wiring, Signal Wiring.
As per IS 694
CE Certified
Generally confirms to IEC Standards
HV Test voltage: 4kV
Specific Insulation Resistance:>20G Ohm*cm
Rated Voltage: Vo/V:450/750V and 1100V Grade
Temperature Range: Fixed installation 30℃ to +105℃ HRPVC
Cross section from 0.5 Sq.mm to 6.00 Sq.mm of 90 mtrs length available in paper corrugated boxes.
Colors available: Red, Yellow, Blue, Black, Green.
Nominal Cross Sectional area of Conductor (Sq.mm) | Number/Nominal Diameter of each strand (mm) | Thickness of Insulation (Nominal)(mm) | In Conduit/Trunking | Unenclosed Clipped Directly to a Surface or On Cable Tray AMPS | Resistance (Max)/Per Km @20oOHMS |
0.50 | 16/0.2 | 0.6 | 4 | 4 | 39.00 |
0.75 | 24/0.2 | 0.6 | 8 | 8 | 26.00 |
1.00 | 32/0.2 | 0.6 | 11 | 12 | 19.50 |
1.50 | 30/0.25 | 0.6 | 11 | 12 | 13.30 |
2.50 | 50/0.25 | 0.9 | 18 | 22 | 7.98 |
4.00 | 56/0.3 | 0.8 | 24 | 29 | 4.95 |
6.00 | 84/0.3 | 0.8 | 31 | 37 | 3.20 |
Panel Wiring, Building wiring, Signal Wiring.
As per IS 694
CE Certified
Generally confirms to IEC Standards
HV Test voltage: 4kV
Specific Insulation Resistance:>20G Ohm*cm
Rated Voltage: Vo/V:450/750V and 1100V Grade
Temperature Range: Fixed installation 30℃ to +105℃ HRPVC
Cross section from 0.5 Sq.mm to 6.00 Sq.mm of 90 mtrs length available in paper corrugated boxes.
Colors available: Red, Yellow, Blue, Black, Green.
Conductor Cross-section In Sq.mm | Outer Dia approx In Sq.mm | Copper index In Kg/km |
0.50 | 2.15 | 4.80 |
0.75 | 2.30 | 7.20 |
1.00 | 2.50 | 9.60 |
1.50 | 3.00 | 14.40 |
2.50 | 3.70 | 24.00 |
4.00 | 4.30 | 36.40 |
6.00 | 4.90 | 58.00 |
Panel Wiring, Building wiring, Signal Wiring, Laying In tubes, Direct laying.
CE Certified
Generally confirms to VDE Standards
HV Test voltage: 2-2.5kV
Specific Insulation Resistance:>20G Ohm*cm
Rated Voltage: Vo/V:300/750V and 1100V Grade
Temperature Range: Fixed installation 30℃ to +80℃
Conductor Bunching: Short lay, Class 5 as per VDE 0295 or IEC 60228 class 5
Cross section from 0.5 Sq.mm to 6.00 Sq.mm of 90 mtrs length available in paper corrugated boxes.
Colors available: Red, Yellow, Blue, Black, Green.
Conductor Cross-section In Sq.mm | Outer Dia approx In Sq.mm | Copper index In Kg/km |
0.50 | 2.10 | 4.80 |
0.75 | 2.40 | 7.20 |
1.00 | 2.60 | 9.60 |
1.50 | 3.00 | 14.00 |
2.50 | 3.70 | 24.00 |
4.00 | 4.30 | 38.00 |
6.00 | 4.90 | 58.00 |
16.00 | 8.00 | 153.00 |
25.00 | 9.80 | 240.00 |
35.00 | 11.00 | 336.00 |
50 | 13.00 | 480.00 |
70.00 | 15.50 | 672.00 |
95.00 | 17.00 | 912.00 |
120.00 | 19.70 | 1152.00 |
150.00 | 21.30 | 1440.00 |
185.00 | 23.50 | 1776.00 |
240 | 27.50 | 23.04.00 |
300 | 29.00 | 2871.00 |
O.E.M, Machine Builders, Power Applications,Flexible Applications, Power Stations.
CE Certified
BIS Certified
Generally confirms to IEC Standards
HV Test voltage: 2.5kV
Rated Voltage: Vo/V:450/750V ^ 600/1000 and 1100V Grade
Temperature Range: Fixed installation -30℃ to +80℃
Conductor Bunching: Short lay, Class 5 as per VDE 0295 or IS 8130
Minimum Bending Radius:Occasional Flexing 15x Cable dia Fixed Application 4x Cable dia.
Conductor Cross-section In Sq.mm | Outer Dia approx In Sq.mm | Copper index In Kg/km |
0.50 | 2.10 | 4.80 |
0.75 | 2.40 | 7.20 |
1.00 | 2.60 | 9.60 |
1.50 | 3.00 | 14.00 |
2.50 | 3.70 | 24.00 |
4.00 | 4.30 | 38.00 |
6.00 | 4.90 | 58.00 |
16.00 | 8.00 | 153.00 |
25.00 | 9.80 | 240.00 |
35.00 | 11.00 | 336.00 |
50 | 13.00 | 480.00 |
70.00 | 15.50 | 672.00 |
95.00 | 17.00 | 912.00 |
120.00 | 19.70 | 1152.00 |
150.00 | 21.30 | 1440.00 |
185.00 | 23.50 | 1776.00 |
240 | 27.50 | 23.04.00 |
300 | 29.00 | 2871.00 |
O.E.M, Machine Builders, Power Applications,Flexible Applications, Power Stations.
As per IS 694
CE Certified
Generally confirms to IEC Standards
HV Test voltage: 4kV
Specific Insulation Resistance:>20G Ohm*cm
Rated Voltage: Vo/V:450/750V and 1100V Grade
Temperature Range: Fixed installation 30℃ to +105℃
oConductor Bunching: Short lay, Class 5 as per VDE 0295 or IS 8130.
Core & Conductor Cross-section In Sq.mm | Width ‘W’ mm | Height ‘T’ mm | Copper index In Kg/km | Cable Weight In Kg/km |
2X1.0 | 7.80 | 5.00 | 18.00 | 69.00 |
2X1.5 | 8.40 | 5.40 | 27.00 | 83.00 |
2X2.5 | 10.00 | 6.40 | 44.00 | 115.00 |
2X4.0 | 11.50 | 7.20 | 71.00 | 156.00 |
2X6.0 | 13.00 | 8.00 | 107.00 | 203.00 |
2X10.0 | 16.00 | 9.60 | 178.00 | 307.00 |
2X16.0 | 18.50 | 11.00 | 284.00 | 436.00 |
2X25.0 | 22.50 | 13.00 | 445.00 | 643.00 |
2X35.0 | 25.50 | 14.50 | 622.00 | 848.00 |
2X50.0 | 29.00 | 16.50 | 889.000 | 1170.00 |
3X1.0 | 10.50 | 5.00 | 27.00 | 92.00 |
3X1.5 | 11.50 | 5.40 | 36.00 | 97.00 |
3X2.5 | 14.00 | 6.40 | 60.00 | 139.00 |
3X4.0 | 16.50 | 7.20 | 99.00 | 212.00 |
3X6.0 | 18.00 | 8.00 | 148.00 | 276.00 |
3X10.0 | 22.50 | 9.60 | 262.00 | 449.00 |
3X16.0 | 26.50 | 11.00 | 412.00 | 647.00 |
3X25.0 | 32.50 | 13.50 | 641.00 | 975.00 |
3X35.0 | 36.00 | 15.00 | 902.00 | 1296.00 |
3X50.0 | 41.50 | 17.00 | 1295.00 | 1808.00 |